Epoxy coated cast iron body has a single victaulic style cover houses both plastic cam checks and a plunger style bronze relief valve hangs below. ZURN WILKINS Model 950 Double Check Valve assemblies are for use on water lines where a health hazard does not exist in the event of a backflow situation. STANDARDS COMPLIANCE (3/4" - 2") ASSE® Listed 1013. The innovative EZSwap™ Pressure Vessel is removed and replaced with the Flush Fitting Tool for faster flushing and testing.

The Zurn Wilkins 375 Reduced Pressure Principle Backflow Preventer provides high hazard protection for all applications. 100mm Wilkins 375 RPZ Valve complete. 93 Only 4 left in stock - order soon. The main body shall be Nylon and the seat disc elastomers shall be silicone. 575 2 1/2-6" relief valve assy Fitting 2Bolt 3 AirBleed 4RVCover 5Nut 6Washer 7Bellofram 8Bellofi’amRet 9RVSpring 10Screw 11 Guide 12O’Ring 13 SmBelloframRet 14SmBellofi-am 15RVBody 16O’Ring. 1379 TYPE TESTED AS/NZS 4020 LIC. Principle Backflow Preventer shall be a WILKINS Model 375XL. Reduced Pressure Principle (1/2 inch - 1 inch).

a ZURN WILKINS water pressure reducing valve, a Model 40XL2 check valve, or a Model 1250XL water ham-mer shock arrester in compliance with industry standards as needed. WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:Fax:. 375 control unit pdf manual download. Model 375AL 100mm - 150mm - Reduced Pressure Principal Assembly. INLET SHUT OFF DIRECTION OF FLOW 30" MAX. 375 Series The Wilkins 375 reduced pressure zone assembly is available in epoxy coated cast iron or stainless steel. If the de-vice fails the test, remove the first and second check valves and thoroughly. 5 inch - 1 inch) Backflow Preventer Repair.

Looking for ZURN WILKINS Reduced Pressure Zone Backflow Preventer, Epoxy Coated Ductile Iron Body, Wilkins 375 Series, Flange (6AVY5)? The flanged, epoxy coated ductile iron body is available with multiple shut-off valve options for installation versatility. View and Download Zurn Wilkins 375 installation, testing, maintenance instructions online. RPZ Backflow Preventer for sprinkler and irrigation systems. Damage to the device could result wherever water hammer and/or water thermal expan- sion could create excessive line pressure. Wilkins 1" 375 Backflow Preventer 1-375 RPZ Reduced Pressure Principle Assembly 4. Wilkins Series wilkins 375 reduced pressure assemblies, manufactured by Zurn, are designed for installation on potable water lines to protect against both back-siphonage and back-pressure of contaminated water into the potable water supply. The 3/4" Wilkins 375 Reduced Pressure Zone began production in and is still currently in production.

Wilkins 375 Wilkins 375. It features high quality plastic cam checks. Wilkins: 1" 375 Reduced Pressure Principle Backflow Preventer. Wilkins 975XL 1 in. Gasket Nuts and Bolts not included. The Zurn Wilkins 375XL Reduced Pressure Principle Backflow Preventer delivers high hazard protection for potable water applications. RPZ Backflow Preventer The Zurn Wilkins 975XL Reduced Pressure Principle Backflow Preventer provides high hazard protection for non-potable water applications.

ZURN WILKINS Model 975 Reduced Pressure Principle assemblies are for use on water lines where a health hazard exists in the event of a backflow situation. The checks are inline modular design, with self contained check assemblies. An external sensing line pressurizes the diaphragm.

Proper performance is dependent upon following these installation instructions and prevailing governmental and industry standards and codes. Standards Compliance (Horizontal & Vertical) ASSE Listed 1013 (3/4" - 2") IAPMO Listed; CSA B64. , Mississauga, Ontario L4V 1L2 Phone:Fax:. com/products/water-safety/backflow-prevention/model-375 Zurn Wilkins Model 375 (. Compare ZURN WILKINS. To view all options, see the Specification Sheet - Model 375. Reduced Pressure Zone Backflow Preventer, Epoxy Coated Ductile Iron Body, Wilkins 375 Series, Flange. The Wilkins 350 is the double check valve assembly.

The Zurn Wilkins 375 Reduced Pressure Principle Backflow Preventer provides high hazard protection for non-potable applications. Assembly shall provide protection where a potential health hazard exists. Wilkins 3/4" 375 Backflow Preventer 34-375 RPZ Reduced Pressure Principle Assembly 9.

PROTECTIVE ENCLOSURE AIR GAP OPTIONAL WATER METER 175 PSIG 180ß F 3/4" 375 RP ZURN WILKINS FLOOR DRAIN MODEL 375XLSAG (SHOWN) OPTIONAL LEAD-FREE STRAINER MODEL SXL WILKIN S XL Capacity thru Schedule 40 Pipe Pipe size 5 ft/sec 7. The 6" Wilkins 375 Reduced Pressure Zone began production in 1998 and is still currently in production. Zurn 34-720A Wilkins Pressure Vacuum Breaker 3/4-Inch. Checks are held in place with retainers. Sold by SprinklerPartsWholesale and ships from Amazon Fulfillment.

The Reduced Pressure Principle Backflow Preventer shall be a WILKINS Model 375. ZURN WILKINS Model 375/475 Series Assemblies are for use on potable water lines where a health hazard exists in the event of a backflow situation. 1379-Type Tested AS/NZS. The model 475 is able to be changed to provide an up and down or vertical piping orientation. 1 STANDARDS COMPLIANCE-Australian Watermark (AS/NZS 2845. Sprinkler Warehouse Pro Alfred Castillo explains why the Zurn Wilkins 375 Reduced Pressure Assembly Fast Test is quickly becoming the contractor&39;s RPA of cho.

BASIC REPAIR KIT The repair kit contains discs, diaphragm, and O-rings SIZE 1 1/4"-2" 2 1/2"-3 375/475 2 1/2"-4" 375A 375/475 375/475 8"-10" 375/475 IMPORTANT FEATURES £ontained springs. MODEL 375 ZURN WILKINS BACKFLOW Reduced Pressure Zone Device VALVE SIZE A B mm mm mmDIMENSIONS IN MILLIMETERS (approximate) WATERMARK AS/NZS 2845. Includes Device and Butterfly Valves and Strainer. com/products/water-safety/backflow-prevention/model-375 Zurn Wilkins Model 375 (4 inch & 6 inch) Backflow Preventor Repair. The 375 features a unique plastic insert cartridge that houses both checks and relief valve in a compact design and sets into a bronze body. Ideal for situations that require winterization, as the whole cartridge. If installed indoors, the installation shall be supplied with an air gap adapter. The relief valve spring is not contained when the cover is removed.

Page 2 of 2 WILKINS a Zurn company, wilkins 375 rpz manual 1747 Commerce Way, Paso Robles, CA 93446 Phone:Fax:IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr. As you can see from their outward appearance they have changed the design to incorporate a removable plastic “vessel” or body. The A model uses a grooved end valve body configuration as opposed to the flanged end valve body. WILKINS Model 375/475 Series Assemblies are wilkins 375 rpz manual for use on potable water lines where a health hazard exists in the event of a backflow situation. Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. 375, and 475 Reduced Pressure Principle Backflow Pre-. In 20 became available in an "A" model (e. The EZSwap®Pressure Vessel provides safe and easy line flushing, quick winterization, and simple maintenance and repair.

Grainger&39;s got your back. Flanged AS2129 Table D / AS4087 Class 16. 3 out of 5 stars 26. The wye pattern, bronze body provides separate access to each check valve and the relief valve for servicing.

Overview Wilkins 375 1" in. To view all options, see the Specification Sheet. Sprinkler supplies shipped fast! If you have trouble, download Adobe Reader. To view all options, see the Specification Sheet - 375XL (SIZES 1/2" - 2"). Looking for ZURN WILKINS Reduced Pressure Zone Backflow Preventer, Epoxy Coated Ductile Iron Body, Wilkins 375 Series, Flange (6AVY4)? After the Model 375 has been prop-erly installed, test the device (see "TEST PROCEDURES").

The repair kits for both models will be the same. Reference wilkins 375 rpz manual Manual is in PDF format. 5 inch & 3 inch) Backflow Preventor Repair. Wilkins Section of the BAVCO backflow reference manual.

View and Download Zurn Wilkins 375 installation, testing, maintenance instructions online. com/products/water-safety/backflow-prevention/model-375 Zurn Wilkins Model 375 (2. Sprinkler Warehouse right parts right price.

WILKINS Model 375 Reduced Pressure Principle Backflow Preventers are for use on potable water lines where a health hazard could exist if a backflow situation were to occur. The model 375 is the rpz reduced pressure principle assembly. RPZ Backflow Preventer Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & more. Model 375 65mm - 250mm - Reduced Pressure Principal Assembly Designed for installation on potable water lines as well as protection against both. The model 375 is a horizontal piping orientation. Wilkins Backflow Preventer RPZ, 4", Model 375A, 4-375A.

Wilkins 375 rpz manual

email: uqiveqy@gmail.com - phone:(523) 137-5957 x 4932

Manual abfo importancia medica y odontologica - Wilkins manual

-> Prensa manual paracencadernação
-> Manual maxi cosi mico ap pdf

Wilkins 375 rpz manual - Service pioneer gmfi


Sitemap 1

Daa78l manual - Manually diablo change